Home
About
Shipping Policy
Contact
My Account
|
Register
|
Call Us:
877-801-5693 /
Español haz click aquí
877-801-5693
CSS3 Menu Dropdowns
Product Categories
Balometer - Flow Hood
Borescopes
Combustion Analyzers
Cool Machines by Dave Krendl
Disinfectant Sanitizing Foggers
Falltech Fall Protection Systems
Fume Extractors
Insulation Machines & Equipment
Insulation Vacuum Systems
Kanomax
Particle Meter - Counter
Safety Equipment - PPE
Envirocleanse-A
Foggers for Pest Control
> E Instruments E8500 E 8500 Flue Gas Emissions Combustion Analyzer
E Instruments E8500 Flue Gas Emissions Combustion Analyzer
E Instruments E8500 E 8500 Flue Gas Emissions Combustion Analyzer
Price
Your Price:
$0.01
Part Number:
7387
Put me on the Waiting List
Quantity
Add to Cart
Email a friend
Product Resources
Customer Reviews
Features
Specifications
Choose Options
Resources
E Instruments E8500 E 8500 Flue Gas Emissions Combustion Analyzer NOx CO2
The E8500 from E Instruments is unsurpassed as the most advanced and powerful portable combustion gas analyzer available on today's market, & is a portable test instrument for EPA compliance of emissions monitoring.
The E8500 Industrial flue gas analyzer can also test and monitor furnaces, boilers, engines, and has many other combustion and emissions applications. A built in thermoelectric chiller quickly and efficiently removes water vapors from flue gas samples to prevent combustion gas bubbling from gas phase into condensate. The E8500 chiller is made for exceptional sample conditioning & handles flue gases to 40 percent water content.
The built in drain pump for condensate automatically pumps accumulated water through the bottom for improved convenience, especially if used for long term monitoring and testing.
The E8500 may have 9 gas sensors total as a combination of 6 electrochemical & 3 NDIR sensors.
E8500 Includes
Condensate automatic drain pump
Thermoelectric chiller built in
NO, CO & O2 sensors
Rechargeable battery pack
110 - 240 Volts AC / 50 - 60 Hertz battery charger
12 Inch (300 millimeter) test probe w/ 10 foot (3 meter) dual hose
Air temperature & stack gas measurements
Differential & draft measurements
Excess air, efficiency and CO2 c
alculations
Internal memory (1000 test results) to use with long term data logging and monitoring
Real time software w/ Bluetooth for PC includes real time reports, graphing and data logging
USB cable
Wireless communication
Operator's manual
Calibration certificate
Protective
carry case
E Instruments E 8500 Features
6 Different electrochemical sensors available
NO2
NO
CO
SO2
O2
H2S
Non dispersive (NDIR) sensors available
High CO, CxHy & CO2
True NOx measurement
Auto range CO dilution for measurements to 20,000 parts per million
2 channel thermometer
Optional remote wireless printer
Gas velocity measurement using optional pitot tube
LCD rotating display
Pre calibrated and field replaceable g
as sensors
Immediate response time
2 channel thermometer
Battery pack
Metal
Unbreakable
Hose Connectors
E8500 Specifications
Parameters
Sensors
Ranges
Resolutions
Accuracies
O2
Electro-chemical
0 - 25 percent
0.1 percent
+/-0.1 percent vol
auto range
CO
Electro-chemical
0 - 20,000 parts per mil.
1 part per mil.
+/-10 percent rdg
CO
Electro-chemical
0 - 8,000 parts per mil.
1 part per mil.
below 300 parts per mil.= +/- 10 ppm
to 2000 parts per mil. = +/- 4 percent
above 2000 parts per mil. = +/- 10 percent
CO
NDIR
0 to 15 percent
0.01 percent
+/- 3 percent rdg
CO2
Calc.
0 to 99.9 percent
0.1 percent
CO2
NDIR
0 to 20 percent
0.1 percent
+/- 3 percent rdg
NO
Electro-chemical
0 - 4000 parts per mil.
1 part per mil.
below 125 parts per mil. = +/- 5 parts per mil.
to 4000 parts per mil. = +/- 4 percent
NO2
Electro-chemical
0 - 1000 parts per mil.
1 part per mil.
below 125 parts per mil. = +/- 5 parts per mil.
to 1000 parts per mil. = +/- 4 percent
Low NO2 / Low NO
Electro-chemical
0 - 500 parts per mil.
0.
1 part per mil.
below 50 parts per mil. = +/- 2 parts per mil.
to 500 parts per mil. = +/- 4 percent
NOx
Calc.
0 - 5000 parts per mil.
1 part per mil
.
SO2
Electro-chemical
0 - 4000 parts per mil
1 part per mil.
below 125 parts per mil. = +/- 5 parts per mil.
to 4000 parts per mil. = +/- 4 percent
CxHy
NDIR
0 to 3 percent
0.01 percent
+/- 3 percent rdg +/- 0.01 percent
H2S
Electro-chemical
0 - 500 parts per mil.
1 part per mil.
below 125 parts per mil. = +/- 5 parts per mil.
to 500 parts per mil. = +/- 4 percent
Tair
Pt-100
14 - 212 degree F
-10 - 99.9 degree C
1 degree F
1 degree C
+/- 3 degree F
+/- 2 degree C
Tgas
Tc K
32 - 1830 deg F
0 - 999.9 deg C
1 degree F
1 degree C
+/- 3 degrees C
+/- 5 degrees F
ΔT
Calc.
32 to 1830 deg. F
0 to 999.9 deg. C
1 degree F
1 degree C
Draft /
Pressure
Bridge
+/- 0 - 40 inH2O
0.1 in H2O
+/- 1 percent rdg
Excess Air
Calc.
1 to infinity
0.01
Gas Velocity
Calc.
0 to 330 feet / sec.
0 to 99.9 meters / sec.
0.1 feet / sec.
0.1 meters / sec
Efficiency
Calc.
0 - 99.9 percent
0.1 percent
Choose Options
Electrochemical Gas Sensors
O2 Sensor 0 to 25 percent - (O)
0 to 8000 ppm CO Sensor auto range dilution to 20000 ppm - (C)
0 to 4000 ppm NO Sensor - (N)
0 to 500 ppm H2S Sensor - (H)
0 to 4000 ppm SO2 Sensor - (S)
0 to 1000 ppm NO2 Sensor - (D)
Non dispersive (NDIR) Sensors
NDIR sensors (none) - (0)
CO2 0 to 20% High CO 0 to 15% and CxHy 0 to 3% Sensors - (ABC)
Sample Test Probes And Hoses
12 Inch (300 millimeter) Test Probe 1470 F (800 C) maximum w/ 10 foot (3 meter) dual hose - (12)
30 Inch (750 millimeter) Test Probe 1470 F (800 C) maximum w/ 10 foot (3 meter) dual hose - (30)
40 Inch (1 meter) Test Probe 2190 F (1200 C) maximum w/ 10 foot (3 meter) Hose - High temp. applications - (40HT)
60 Inch (1.5 meter) Test Probe 2190 F (1200 C) maximum w/ 10 foot (3 meter) Hose - High temp. applications - (60HT)
E Instruments E8500 Datasheet