Home
About
Shipping Policy
Contact
My Account
|
Register
|
Call Us:
877-801-5693 /
Español haz click aquí
877-801-5693
CSS3 Menu Dropdowns
Product Categories
Balometer - Flow Hood
Borescopes
Combustion Analyzers
Cool Machines by Dave Krendl
Disinfectant Sanitizing Foggers
Falltech Fall Protection Systems
Fume Extractors
Insulation Machines & Equipment
Insulation Vacuum Systems
Kanomax
Particle Meter - Counter
Safety Equipment - PPE
Envirocleanse-A
Foggers for Pest Control
> TED Pro MTU-HV MTU HV Three Phase Commercial Energy Monitor with CTs
TED Pro MTU-HV 3-Phase Commercial Energy Monitor with 3 400 Amp Current Transformer Clamps
TED Pro MTU-HV MTU HV Three Phase Commercial Energy Monitor with CTs
Price
Your Price:
$299.95
Part Number:
7893
Put me on the Waiting List
Quantity
Add to Cart
Email a friend
Product Resources
Customer Reviews
Features
Specifications
Choose Options
Resources
TED Pro MTU-HV MTU HV Three Phase Commercial Energy Monitor with 3 400 Amp CTs
The TED MTU-HV Energy Monitor is an innovative system designed for use in government, commercial & residential buildings and smaller industrial complexes.
The TED MTU-HV enables you to monitor and manage your energy usage through energy cost and use awareness. Energy use & alerts are presented through the Internet, computer, with a custom display, with mobile devices, email messages or by text.
The system may optionally be configured for automatic adjustments to your thermostat settings or to turn off electrical loads which are based on user-selectable criteria like electricity cost, total usage, budget, time of the day, or by request from utility companies or electric providers.
The TED MTU HV is engineered to work with all 3 phase electrical systems anywhere on the globe & is compatible with many energy or demand rate billing systems which include fixed, time of use, step / tiered, demand, seasonal or all combinations of the mentioned methods.
The (MTU) Measuring Transmitting Unit measures energy consumption, current, voltage, power factor and demand. Generally, the MTU-HV is located within the main electrical panel & transmits the information obtained, over the existing electrical wires, using state of the art (PLC) Power Line Carrier communications to the Energy Control Center which receives & interprets electrical data. Multiple MTU-HV units may be used to supply individual measurements of loads or panels. For systems utilizing wind, solar or other types of generation, multiple MTU HV units will communicate user power consumption, generation & net, from or to the utility.
Package Includes
Measuring Transmitting Unit (MTU)
3 - 400 Amp (CTs) Current Transformer Clamps
MTU Power cable
Ethernet cable
System & Utility Rate setups are intuitive and simple with a PC that runs TED web based setup wizards.
Numerous options available
Multiple MTU-HV units can be added for separate measurements of various loads and generation
The TED Spyder mounts beside or in your electrical panel & connects with the MTU-HV. TED's Spyder records detailed electricity usage of a maximum of 8 multi phase or single circuits. Each reading is stored by the ECC internally to display. 2 Spyders may be attached to every MTU-HV, creating a maximum of 16 independent circuits which can be measured for each MTU-HV. (The Spyder system is available in mid 2013)
Display Devices
Wired in Display connected to the ECC directly
Wireless Display (Optional) w/ battery backup is mountable anywhere, even carry it around while load checking
Measuring Transmitter Unit MTU-HV
Service Types
All single or 3 phase
Three phase 4W Wye
Three phase 3W Delta
Three phase 4W Hi LegDelta
Max. voltage Phase / Phase
600 Volts
Max. voltage Phase / Neutral
277 Volts
Minimum Voltage
180 Volts
Max. Current per Phase
400A (1200A *Note 1A)
Max. wire size
500 MCM (25mm OD)
Voltsoltage Measurements
Voltsoltage Divider Circuit
Current Measurements
400A:3 Volts Split-Core CTs
Operating Temp.
-40 deg. C < TA < +50 deg. C
Energy Calculations & Measurement
Analog Devices
ADE7854ACPZ
Accuracy Overall
+/- 2 percent (better than)
Transmit and Measure Energy
+/- 1 Watt
Transmit and Measure Demand
+/- 1 Volt A
Transmit and Measure Voltage
+/- 0.1 Volt
Transmit and Measure Phase Currents
+/- 1 Amp
Transmit and Measure Power Factor
+/- 0.1 percent
Communications
Ethernet / PLC
PLC System
IT700 Yitran System
ECC Data Receiving Units
Works with Three phase and Single phase MTU
Y
Max. Voltage Phase / Neutral
277 Volts
Min. Voltage Phase / Neutral
95 Volts
Available Cord Types
AU, UK, EU, UL
Operating Temp.
+5 deg. C < TA < 40 deg. C
Communication Methods
Wifi, Ethernet, PLC, XBee, USB, ZigBee
Port - USB 2.0
1
Port - USNAP 2.0
2
Port Display
1
Compatible with ZigBee SE2.0 SmartMeter
Y
Accepts Demand Reduction Requests from theutility
Y
Max. # of MTUs on 1 system
4
Max. Spyders on 1 MTU
2 (8 circuits with eachSpyder unit)
Max. # of measured loads
16 (in future release)
LED - Power on
Blue
LED - Link status
LED Transmit / Receive
Green/Red
Energy Use Meter
Yellow / Green / Red
*Note 1A Measures up to 1200 Amps w/ 3 Parallel 400 Amp feeds using (optional) ADP CT Adapter
Choose Options
Accessories
Wireless handheld portable display stand & charger with ZigBee USNAP card [+$149.00]
MTU with 3 - 400 Amp CTs [+$299.95]
Set of 3 - 400 Amp CTs [+$99.95]
MTU (with no CTs) [+$219.95]
Single 400 Amp CT [+$34.95]
ADP - CT harness adapter [+$12.50]
ECC - Commercial [+$349.95]
TED Pro Brochure
TED Pro Manual
x